ROD-L M100DC

 

MODEL M100DC

DC Hipot Test Instrument

Safe, Fast, Efficient

  • Performs Dc dielectric withstand test up to 5.5 KVDC at 10 milliamperes (5mA standard)
  • Performs concurrent ground continuity test
  • ARC and OVERCURRENT detection circuits
  • Fast HV shutdown within 2 milliseconds
  • Fast discharge of Device Under Test (DUT) and other test standards

Production/Quality Assurance Testing

  • Fully automatic test cycle
  • Detects and indicates the following
    • Test Ready (security ground chassis sensed)
    • Test in Progress
    • Test Passed
    • Test Failed
  • Following test parameters easily preset via rear panel potentiometers
    • Voltage ramp
    • Test time
    • Test voltage
    • overcurrent trip point
  • Switch-selectable ramp and rest time combinations
  • Arc detection circuit
  • Overcurrent detection circuit
  • Solid state HV generation and control system for reliability
  • Switchable “burn” featured permits destructive testing by maintaining output voltage, following failure, to the DUT throughout duration of preset test time
  • Can be interconnected with M25 Ground Continuity Test Instrument or any ROD-L AC Hipot Test Instrument to simplify multiple testing requirements

For specifications, call ROD-L or download the PDF and refer to page 2.

pdf

 

Continuos Ground Continuity Monitoring

  • Monitors Ground Continuity of DUT before and during each Hipot Test
  • Senses for 0.5 ohm (standard), at approximately 1.5 VAC
  • Loss of safety ground connection during test causes high voltage to shut down with both audible and visual failure indication
  • Inhibits application of high voltage if the security chassis ground is not secure

Superior Safety Features

  • Front panel receptacle is rated to 8000 VAC
  • Front panel receptacle prevents direct operator exposure to high voltage during test
  • Shutdown within 2 milliseconds after dielectric breakdown, overcurrent or ground continuity fault
  • Electronically controlled output voltage ramp rate circuit guarantees consistently smooth ramp
    Visual (audible optional) indication of high voltage applied to DUT
    Discharge circuit provides for rapid discharge of DUT following shutdown
    Visual and audible indication of the following:
    • Arc detection
    • Excessive overcurrent flow
    • Ground continuity test failure

 


ROD-L M100DC | Test Equipment | ROD-L

ROD-L Electronics 1.800.548.6305. Hipot, Ground continuity & leakage current testers. Free lifetime warranty. Precise fault detection. Made in USA.