| products » M100BVS5 and M500BVS5 |
ROD-L M100BVS5 and M500BVS5 |
|
|
|
|
|
All ROD-L hipot testers have adjustable electronically controlled test voltage ramp control and timing circuits. In addition, ROD-L AC and DC hipot testers interconnect to simplify multiple testing requirements. Each are compatible with all ROD-L Ground Continuity and Leakage Current test instruments. |
|
|
|
|
|
MODEL M100BVS5 and
MODEL M500BVS5 |
 |
| Hipot and Concurrent Ground Continuity Test System |
 |
Now you can perform safe, rapid testing for dielectric withstand and ground continuity in one simple operation.
The ROD-L Hipot testers are designed to perform the tests specified by UL, IEC, CSA, VDE, FCC and others. The ROD-L product line has been designed with emphasis on safety, efficiency, and on speed with which the test can be made.
Safe, Fast Efficient
Fully programmable test parameters |
 |
|
|
 |
Electronically controlled voltage rate-of-rise to ensure gradual, smooth and consistent rise time (eliminates harmful voltage spikes) |
|
|
 |
Electronically controlled voltage shutdown. Fast shutdown (2 ms) prevents harm to operator and protects the device under test (DUT) |
|
|
 |
Electronic, adjustable timing circuit to provide accurate, reliable test time (1 sec to 90 sec) |
|
|
 |
Applies a test potential of up to 5000 VAC at 50 Front panel receptacle, rate to withstand 8000 VAC, for direct plug-in of DUT or for plug-in of test fixture; provides maximum safety and dramatically reduces the time required to perform the test |
|
|
 |
Performs ground continuity test of 0.5 ohm resistance standard (.1 ohm available) at approximately 1.5 VAC |
|
|
 |
Security chassis ground test to enhance operator safety |
|
|
 |
Completely solid state reliability |
|
|
 |
TTL logic allows optional computer interface |
|
|
 |
Rack mountable |
|
|
 |
Performs hipot test requirements specified by UL, CSA, IEC, VDE, FCC and others |
|
|
 |
Detects arcs as short as 10 microseconds duration |
|
|
|
 |
|
|
|
For specifications, call ROD-L
or download the PDF file and refer to page 4. |
|
|
| Simple Operation |
|
| The hipot tester applies the test voltage to the DUT for a duration of time from 1 second to 90 seconds. The DUT simply plugs into the front panel outlet, rather than being attached with clip leads. Clip leads and the ROD-L Test Probe can be used, however, for devices without a power cord. |
|
| Test limits for leakage current are preset by the user via the rear panel control. In the even of failure, automatic circuitry turns off the high voltage within 2ms, lights the "failure" lamp, and sets off an audible alarm. Both the audible alarm and visual alarm must be reset manually. |
|
| Use a ROD-L hipot tester for quality assurance testing, incoming inspection and in-product development. |
|
|
 |
|
 |
 |
OPTIONS FOR THIS SYSTEM |
|
|
|
|
| 01 |
|
|
Remote Control (digital) |
| 02 |
|
Front Panel Test Time Control |
| 03 |
|
Front Panel Voltage Ramp Control |
| 05 |
|
Hands Off Operation |
| 06 |
|
Rear Panel Lockout Cover |
| 08 |
|
Six Switch-Selectable Failure Points |
| 10 |
|
Audible Test Tone |
| 15 |
|
Rack Mount Kit |
| 18 |
|
Ohms Sense (with Option 24A) |
| 22 |
|
Front Panel Voltage Adjust |
| 23 |
|
Digital Meters (voltage and current) |
| 24 |
|
Blank Front Panel |
| 27 |
|
"No Load" Trip Point Setting |
| 28 |
|
Two Switch-Selectable Current Scales |
| 29 |
|
Three Switch-Selectable Voltages |
 |
 |
 |
|
|
|